Comunello CU 230V HP Instrucciones De Uso Y De Instalacion página 25

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
by Pushbuttons or remotes. In contrast, during the closing movement a
command sent by the Pushbuttons or the remotes will reverse the direction
of movement. This operating mode is invaluable when the automation
includes a loop detector.
In the default configuration the control unit is set with the Condominium
function disabled; if the Condominium function is required, proceed as
follows: use the SELECT key to select blinking LED L3 and then press the
SET key: LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
4. MOTOR TIME (Operator run time programming, max 4 minutes):
The control unit is factory set with Operator run time of 30 seconds without
deceleration.
If the run time of Operators 1 and 2 must be changed, programming must
be carried out with the gate closed as follows: use the SEL key to select
blinking LED L4 and then press the SET key momentarily; Operator 1 will
start the opening cycle; when the required deceleration starting point is
reached, press the SET key again; LED L4 will start blinking more slowly and
Operator 1 will decelerate. On reaching the required position, press SET to
terminate the Opening cycle. At this point LED L4 will revert to the normal
blinking rate and Operator 2 will start the opening cycle: repeat the run time
programming operation for Operator 2. When motor times programming
for the opening cycle is finished, Operator 2 restarts immediately in the
closing cycle: repeat the operations described above for the Closing cycle
of Operator 2 followed by Operator 1.
If you do not require the control unit to perform the deceleration, during
programming, when the opening and closing cycles have been completed
press the SET key twice consecutively rather than just once.
If the control unit is used in the single Operator configuration (dip switch
SW1 OFF), programming of the run time of Operator 2 is not executed.
During programming, instead of the SET key on the control unit you can use
the button on the remote, provided the remote has been saved beforehand.
5. PAUSE TIME (Automatic closing time programming 4 min. max.):
The control unit is factory set with automatic closing disabled. If you wish
to enable automatic closing proceed as follows: use the SEL key to select
blinking LED L5 and press the SET key momentarily; now wait for a time
equivalent to the required time; press the SET key again momentarily
and at the same time the automatic closing time will be saved and LED
L5 will remain steady on. If you wish to restore the initial condition (no
automatic closing) select blinking LED L5 and then press the SET key twice
consecutively in an interval of 2 seconds. The LED will switch off and the
operation will be completed.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand.
6. LEAVES DELAY (15 sec. max leaf delay programming):
The control unit is factory set with leaves opening and closing delay disabled
(4 sec.). If the control unit is used in the configuration for an automation
with 2 operators, it may be necessary to set a different leaves delay time;
programming must be performed with the gate closed as follows: press the
SELECT key to select blinking LED L6 then press the SET key momentarily;
now wait for a time equivalent to the desired time interval and then press
the SET key again momentarily, at the same time the fixed 4 second leaves
opening delay and the closing delay for the programmed time will be saved
and LED L6 will remain steady on.
If you want to deactivate this function (without leaves delay), select blinking
LED L6 and then press the SET key twice consecutively in a time interval
of 2 seconds, at the same time the LED will switch off and the operation
will be terminated.
7. AUTOMATIC PROGRAMMING (PRG AUTOM):
The control unit allows Automatic Programming (SIMPLIFIED).
Press the SEL key to select blinking LED L7 and then press the SET key
and hold it down; Operator 2 will perform closing until reaching the limit
switch or end stop, thereafter the Operator 1 movement will be repeated.
If the Operators move in the opposite direction to the described direction,
release the SET key, disconnect the control unit from the power supply and
change the setting of Dip Switch SW2 to change the direction of run of the
required operator without having to rewire the connections. If the Operators
sequence is correct, the control unit completes the Auto programming
stage by performing a complete opening and closing cycle (keep the SET
key pressed until the end of the Auto Programming procedure). During the
Auto Programming procedure, the Deceleration cycle is set automatically at
approximately 15% of the complete cycle.
During Automatic Programming, instead of the SET key on the control unit
you can use the button on the remote, providing the remote has been
saved beforehand.
Warning: Automatic Programming is not available without limit
switches.
EXTENDED MENU 1
The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you wish to enable the functions described in Extended
Menu 1, proceed as follows: select blinking LEV LED and press SET once.
The LED will start blinking. This means there will be 30 seconds to select
the functions of Extended Menu 1 using the SELECT and SET keys; once
an additional 30 seconds have elapsed, the control unit reverts to the main
menu.
L1
PERSON PRESENT
L2
PEDESTRIAN /
SINGLE LEAF PUSHBUTTON
L3
PEDESTRIAN PUSHBUTTON /
DS3
L4
FOTOTEST
L5
DS2 STP IN CLOSING
L6
DS1 PARTIAL REVERSAL
L7
NC AS 8K2
LEV
MENU LEVEL
1. HOLD-TO-RUN:
The control unit provides the opportunity to set the "Hold-to-run" function.
If you wish to enable this function, proceed as follows: ensure you have
enabled Extended Menu 1 (alternate blinking 1 0 1 0 1 0 of menu LED
LEV) and then use the SEL key to select blinking LED L1 and press the
SET key; LED L1 becomes steady on and the operation will be completed.
With hold-to-run enabled, using either the remotes or the Pushbuttons to
operate the gate, the following operation will be obtained: the command
must be maintained constantly to move the gate. When the command is
released, movement will stop immediately. Repeat the procedure if you
wish to restore the previous configuration.
2. SINGLE LEAF OR PED. BUTTON = OPEN, PED. BUTTON = CLOSE:
The control unit allows a NO Pushbutton to be connected (CN2 input no.
10) to activate the gate in Pedestrian Opening mode. It is however possible
to use this input to connect a NO pushbutton operating in a different
manner. If you wish to enable the "Single Leaf" function, proceed as follows:
ensure you have enabled Extended Menu 1 (alternate blinking 1 0 1 0 1
0 of menu LED LEV) and then use the SEL key to select blinking LED L2
and press the SET key; LED L2 becomes steady on and the operation will
be completed. With this function enabled, the Pushbutton can be used
to activate exclusively Operator 1 (refer to the heading "Single Leaf"). In
contrast, if you wish to enable "OPEN-CLOSE" mode in order to use the
Pedestrian Pushbutton to activate exclusively opening of the gate and the
P/P Pushbutton to (CN2 input no. 11) to activate exclusively closing of the
gate, repeat the operation described above, pressing the SEL key twice
(LED L2 will blink rapidly) instead of just once. Repeat the procedure if you
wish to restore the initial configuration.
3. PEDESTRIAN PUSHBUTTON / DS3:
The control unit allows a NO Pushbutton to be connected (CN2 input
no. 10) to activate the gate in Pedestrian Opening mode. However, this
input can be used to connect a DS3 photocell (NC): make sure you have
enabled Extended Menu 1 (alternate blinking 1 0 1 0 1 0 of menu LED LEV)
and then use the SEL key to select blinking LED L3 and press the SET key;
LED L3 becomes steady on and the operation will be completed. Repeat
the procedure if you wish to restore the previous configuration.
4. FOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled. If you wish
to enable the photocells test proceed as follows: ensure you have enabled
Extended Menu 1 (blinking 1 0 1 0 1 of LED LEV) and then use the SEL key
to select blinking LED L4 and press the SET key; LED L4 becomes steady
on and the operation will be completed. Repeat the procedure if you wish
to restore the previous configuration.
5. DS2 CLOSING STOP:
The control unit allows the operation of input DS2 to be modified. If you want
DS2 to trip also during closing (stopping of the gate leaf). If in Automatic
operating mode and once the passage is free, the gate resumes the closing
manoeuvre, proceed as follows: ensure you have enabled Extended Menu
COMUNELLO ®Copyright 2014 - All right reserved
ON
OFF
SINGLE LEAF
PEDESTRIAN
PUSHBUTTON
DS3
PEDESTRIAN
PUSHBUTTON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1 FLASH
25
loading