Setting up the machine
5.9 Setting a joblist
You can set the following functions with each joblist.
– Delete after process: Each job is deleted as soon as it
is completed.
– Additional cross sections: An additional connector can
be used in slot 12 of the feeder.
– Automatic processing: The job list is processed auto-
matically.
– Additional information
► Open the menu Settings.
► Open the menu General settings
► Tap Joblist.
Figure 5.11 Menu General settings/Joblist
► Tap the arrow buttons to enable (On) oder disable (Off)
the respective function.
► Leave the menu.
5.10 Adjusting the interfaces
► Open the menu Settings.
► Open the menu General settings
► Tap Device.
Figure 5.12 Menu General settings/Device
40
► With External Communication choose the desired be-
haviour in combination with the Weidmüller WMC:
– 1 = Event-Handling
– 2 = Polling procedure
► Choose the desired baud rate für the RS232 interface.
► Leave the menu.
5.11 Resetting daily values
► Open the menu Info/System.
Figure 5.13 Menu Info/System
► Tap the round arrow to reset the daily counters for cy-
cles and length.
► Leave the menu.
2819930000/02/06.2022