ROBLIN Vizio/3 Centrale Instrucciones De Instalación E Utilización página 10

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
GB
IN THE EXTRACTION MODE:
a. Fit the non-return backflow flaps C over the round outlet item 6 on top of the canopy while pressing
down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connec-
tions with appropriate clamping rings or adhesive tape (Fig. 8).
b. Before fitting the chimney to the canopy make the electrical connection as described in the section
titled ELECTRICAL.
c. Each top and lower chimney stack consists of two sections. Place the top chimney with the slops fac-
ing downwards (Fig. 6c - item 7a) when installing the ducting version and secure the chimney stacks to
the brackets using the M4 screws provided.
d. Check the vertical of the chimney.
e. Place the lower chimney 7b as illustrated in Fig 9 &10.
IN THE RECIRCULATION MODE:
a. Fit the recirculation spigot R onto the chimney bracket using the same fixing screws Fig.6a.
b. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot
and secure the connections with appropriate clamping rings or adhesive tape (Fig. 6c).
c. Make the electrical connection as described in the section titled ELECTRICAL.
d. Each top and lower chimney stack consists of two sections. Place the top chimney with the slops fac-
ing upwards (Fig. 6c - item 7a) when installing the recirculation version and secure the chimney stacks
to the brackets using the M4 screws provided.
e. Check the vertical of the chimney.
f. Place the lower chimney 7b as illustrated in Fig 9 &10.
9) Check the connectors of the motor as illustrated in Fig. 11.
10) Test the lights and the fan motor.
11) Remove the metal grease filters. Insert the charcoal filter into the base of the motor housing and
secure the filter with two securing straps A as illustrated Fig. 6d.
12) Fit the metal grease filters.
13) Fit the 2 + 2 deflectors Item 9.
8
loading