Throttle Control - DeWalt D55672 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2. Turn knob clockwise to increase regulated pressure and
counterclockwise to decrease regulated pressure.
3. When desired pressure is shown on the regulated pressure
gauge push knob in to lock.

THROTTLE CONTROL

When maxi mum air tank pres sure is reached and the unloader valve
vents air, it activates the throttle control on the engine. This gas
saving feature holds the engine at a factory-set idling speed until air
pressure in the air tank drops to reset pressure. The unloader valve
then reactivates the throttle control and accelerates the engine to
full throttle.
LOW OIL SHUT DOWN SENSORS
The air compressor engine and pump are equipped with low oil
shutdown sensors. These are safety devices designed to protect
your engine and pump from damage in the event the oil level in the
crankcase is below minimum.
If the oil in the pump or engine gets low while the air compressor is
running it will automatically shut down the engine and will not restart
until oil is added to the engine or pump. If the oil is low before start-
up, the engine will not start until oil is added.
NOTE: The low oil shutdown sensors are very sensitive. You
must fill the engine and pump to the full mark on the dipstick to
inactivate this safety device.
INSTALLATION
Assembly (Fig. 1)
INSTALLING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSI.
2. Apply sealant tape to hose threads.
3. Assemble hose to air outlet (G). IMPORTANT: Do not assemble
splitters directly to the air outlet (G).
NOTE: Assembling quick connect bodies to air outlet (G) and quick
connect plugs to hose ends make connecting and disconnecting
hoses simple and easy. Quick connect bodies and plugs are
available for purchase from your local dealer or authorized service
center.
DISCONNECTING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSI.
2. Remove hose(s) from air outlet(s) (G).
Lubrication and Oil
ENGINE
1. The engine was filled WITH oil at the manufacturer. Check engine
oil level before operating unit. If necessary, fill engine to the
appropriate level with recommended oil, see engine's instruction
manual supplied by engine manufacturer for correct procedure.
2. Add fuel to engine. See engine's instruction manual supplied by
engine manufacturer for correct procedure.
WARNING: Risk of explosion or fire. Gasoline vapor is highly
flammable. Refuel outdoors preferably, or only in well-ventilated
areas. Do not refuel or check gasoline level while the engine is
running. Do not store, spill, or use gasoline near an open flame,
a source of sparks (such as welding), or near operating electrical
equipment.