Porter Cable C3101 Manual De Instrucciones página 17

Compresor de apilamiento lateral
Idiomas disponibles

Idiomas disponibles

Risk of Unsafe Operation. Unit cycles automatically when
power is on. When servicing, you may be exposed to voltage sources,
compressed air, or moving parts. Before servicing unit unplug or disconnect
electrical supply to the air compressor, bleed tank of pressure, and allow the
air compressor to cool.
PROBLEM
excessive
tank pressure
- safety valve
pops off
air leaks at
fittings
air leaks at
or inside
check valve
air leaks at
pressure switch
release valve
air leaks in air
tank or at air
tank welds
air leaks
between head
and valve plate
Pressure
reading on
the regulated
pressure gauge
drops when
an accessory
is used
air leak from
safety valve
TROUBLESHOOTING
CAUSE
Pressure switch does
not shut off motor when
compressor reaches
"cut-out" pressure.
Pressure switch "cut-
out" too high.
Tube fittings are not
tight enough.
Check valve seat
damaged.
Defective pressure
switch release valve.
Defective air tank.
leaking seal.
It is normal for "some"
pressure drop to occur.
Possible defect in
safety valve.
Move auto/off lever to the "off"
position, if the unit does not shut off
contact a Trained Service Technician.
Contact a Trained Service Technician.
Tighten fittings where air can be
heard escaping. Check fittings
with soapy water solution. Do
NoT oVeR TIGHTeN.
a defective check valve results in
a constant air leak at the pressure
release valve when there is pressure in
the tank and the compressor is shut
off. Replace check valve. Refer the To
Replace or Clean Check Valve in
the Service and Adjustments section.
Contact a Trained Service Technician.
air tank must be replaced.
Do not repair the leak.
Do not drill into, weld or otherwise
modify air tank or it will weaken. The
tank can rupture or explode.
Contact a Trained Service Technician.
If there is an excessive amount of
pressure drop when the accessory
is used, adjust the regulator as
instructed in the Operation section.
NOTE: adjust the regulated
pressure under flow conditions
(while accessory is being used).
operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.
17 - eNG
CORRECTION
Risk of bursting.
loading