Checkings And Maintenance - Lamborghini Caloreclima XILO D 20 MC W TOP U/IT Manual Para El Usuario

Caldera mural a gas alto rendimiento - modulante
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

CHECKS AND MAINTENANCE
G Prima di avviare la caldaia far verificare da Personale Qualificato "LAMBORGHINI SERVICE":
that the data on the information plate corresponds to that required by the gas, electrical and water
a)
supply networks;
b)
that the pipes which branch off from the boiler are lined with suitable thermally-insulated sheathing;
the proper functioning of the flue pipe;
c)
d)
that the comburent air flow and the fumes evacuation take place properly in accordance with the
regulations in force.
e) that correct aeration and maintenance are possible in case of installation in the furniture.
G
The transformation from a gas (methane or liquid gas) to a gas of another group, which can also be
made with the boiler installed, must be made exclusively by qualified personnel.
G
Ensure that the installer has connected the boiler safety discharge to a waste. In the case of the contrary
the intervention of the safety valves could flood the premises and the manufacturer would not be held
responsible for this.
G
Ensure that the piping of the installation is not used as an earth outlet for other installations; beyond not
being ideal for such a use it could in short bring serious damage to the other appliances connected to it.
G
Ask qualified personnel "LAMBORGHINI SERVICE" to check:
the internal and external tightness of the gas system;
a)
that the gas delivery is that required by the boiler output;
b)
c)
that the type of gas is suitable for the boiler;
d)
that the pressure of gas supply is within the values stated on the boiler plate;
e)
that the gas installation is the correct size and equipped with all the safety and checking devices
prescribed by the current regulations.
G
Ask periodically to check the proper functioning and the good state of the flue exhaust.
G
Ensure that the electrical system has been confirmed by qualified personnel to be adequate for the power
required by the appliance itself.
G
The electricity supply cable must not be replaced by the user, but by qualified personnel only.
G
The electrical safety of the appliance is attained only if the same has been connected to an effective
system earthed in accordance with the current regulations. The verification of this fundamental prerequisite
should be made by qualified persons as the manufacturer will not be responsible for damage caused by
the lack of adequate earthing of the installation.
12
Tabla de contenido
loading

Este manual también es adecuado para:

Xilo d 20 mcs w top u/it

Tabla de contenido