Schumacher Electric Farm & Ranch FR01334 Manual Del Usuario página 13

Idiomas disponibles

Idiomas disponibles

ABORTED CHARGE
If charging cannot be completed normally, charging will abort. When charging
aborts, the charger's output is shut off and the CLAMPS REVERSED/BAD
BATTERY
battery. Check the battery and replace, if necessary.
DESULFATION MODE
If the battery is left discharged for an extended period of time, it could become
sulfated and not accept a normal charge. If the charger detects a sulfated battery,
the charger will switch to a special mode of operation designed for such batteries. If
successful, normal charging will resume after the battery is desulfated. Desulfation
could take 8 to 10 hours. If desulfation fails, charging will abort and the CLAMPS
REVERSED/BAD BATTERY
13. MAINTENANCE AND CARE
A minimal amount of care can keep your battery charger working properly for years.
• Clean the clamps each time you are finished charging. Wipe off any battery fluid
that may have come in contact with the clamps, to prevent corrosion.
• Occasionally cleaning the case of the charger with a soft cloth will keep the finish
shiny and help prevent corrosion.
• Coil the input and output cords neatly when storing the charger. This will help
prevent accidental damage to the cords and charger.
• Store the charger unplugged from the AC power outlet in an upright position.
• Store inside, in a cool, dry place. Do not store the clamps clipped together, on or
around metal, or clipped to the cables.
(red) LED will light. Do not continue attempting to charge this
(red) LED will light.
• 13 •
loading