TROUBLE: DRIVER BLADE STUCK DOWN (DOES NOT RETURN)
PROBLEM
1. Jammed fastener
2. Damaged or worn return system
3. Debris in nosepiece
4. Damaged driver blade assembly
REMEDy
1. Remove battery pack from tool. Refer to "jam clearing" on page 13 for details.
2. Replace return system; see page 21 or see authorized service center
3. Clean nosepiece
4. Replace drive assembly; see page 23 or see authorized service center
TROUBLE: TOOL OPERATES, BUT DOES NOT DRIVE THE
PROBLEM
1. Battery pack not charged, or battery pack is damaged.
2. Depth adjustment set too shallow
3. Tool not firmly applied to workpiece
4. Material and fastener length too rigorous an application
5. Damaged or worn driver blade tip
6. Damaged or worn driver/return assembly
REMEDy
1. Charge or replace battery
2. Rotate depth adjustment wheel to a deeper setting
3. See instruction manual
4. Choose appropriate material or fastener length
5. Replace driver/return assembly; see page 23 or see authorized service center
6. Replace driver/return assembly; see page 23 or see authorized service center
TROUBLE: TOOL OPERATES PROPERLy (MOTOR RUNS AND
PROBLEM
1. No fasteners in magazine
2. Wrong size or angle fasteners
3. Debris in nosepiece
4. Debris in magazine
5. Worn magazine
6. Damaged or worn return system
7. Damaged or worn driver blade
8. Damaged follower spring
REMEDy
1. Load fasteners into magazine
2. Use only recommended fasteners
3. Clean nosepiece
4. Clean magazine
5. Replace magazine; see authorized service center
6. Replace return system; see page 21 or see authorized service center
7. Replace driver assembly; see page 21 or see authorized service center
8. Replace spring; see authorized service center
Trouble Shooting Guide (continued)
FASTENER FULLy
TOOL FIRES), BUT NO FASTENER DRIVEN