Franke PAC 5 GAV-MTC Instrucciones Para El Uso E Instalacion página 18

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Technical Data
Appliance cat. II 2H3+
Type of gas
NATURAL GAS
(methane)
G20
20 mbar
Liquid petroleum gas
(LPG)
G30-G31
30/37 mbar
Table of recommended pans
Burner
Auxiliary
Semi-rapid
Mini triple crown
The use of larger pans than those given could lead to overheating of the knobs and top.
Franke is not liable for any damage deriving from such incorrect use.
Overall rated heat capacity: see dataplate on underside of hob.
Air necessary for combustion: 2 m
Power supply voltage 220/240 V 50-60 Hz.
The appliance is compliant with the following EU Directives:
– 90/396/EEC (Gas):
– 73/23/EEC of 19/02/73 (Low Voltage);
– 89/336/EEC of 03/05/89 (Electromagnetic Compatibility);
– 93/68/EEC of 22/07/93 and subsequent modifications.
14
Burner
auxiliary
semi-rapid
mini triple crown
auxiliary
semi-rapid
mini triple crown
3
/h per kW of power - see dataplate.
Total rated heat
Injector
capacity
marking
in kW
72
1,000
97
1,750
118
2,500
50
1,000
65
1,750
82
1,500
Ø Pan in cm
from Ø 8 to Ø 14
from Ø 14 to Ø 20
from Ø 24 to Ø 28
Heat capacity
reduced
in kW
0,650
0,700
1,500
0,650
0,700
1,900
loading