LF allen + roth VFL-GI35D-20 Manual Del Usuario página 12

Accesorio para chimenea a gas lavaglass
Idiomas disponibles

Idiomas disponibles

INSTALLATION
CHECK GAS TYPE
Make sure your gas supply is correct for the gas fireplace insert. If supply is not correct, do not install
the gas fireplace insert. Call your installer to adjust the gas supply if necessary.
SIZING REQUIREMENTS
Minimum Firebox Size
Height
20 in.
17 in.
GAS FIREPLACE INSERT CLEARANCES
CAUTION: If you install the heater in a home garage
• Heater pilot and burner must be at least 18" above floor.
• Locate heater where moving vehicle will not hit it.
For convenience and efficiency, install gas fireplace insert
• Where there is easy access for operation, inspection and service
• In coldest part of room
• If this appliance is to be installed directly on carpeting, tile or other combustible material, other than
wood flooring, the appliance must be installed on a metal or wood panel extending the full width and
depth of the appliance.
Minimum Clearances For Side Combustible Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace to any combustible material and wall should
follow diagram in Figure 3.
B. Clearances from the top of the fireplace opening to the ceiling should not be less than 36".
WARNING: Maintain the minimum clearances. If possible, provide greater clearances from the
floor, ceiling, and adjoining wall than required.
Minimum Fireplace Clearance to Combustible Materials
Gas fireplace
insert size
20 in.
WARNING: Seal any fresh air vents or ash clean-out doors located on the floor or wall of fire
place to prevent drafting caused by pilot outage or sooting. Use a heat-resistant sealant. Do
not seal chimney flue damper.
Depth
Front Width
14 in.
28 in.
Fig. 3
From edge of fireplace opening to side wall
12
Rear Width
20 in.
16 in.
loading

Este manual también es adecuado para:

5228492