Important; Grounding Instructions - Briggs & Stratton ELITE Serie Manual Del Operario

Ocultar thumbs Ver también para ELITE Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

OPERATION
Air Compressor Operating Location
Locate the air compressor in a clean, dry and well-ventilated
area for operation.The air compressor should be placed at
least 12 inches (30 cm) away from walls or other
obstructions that could interfere with airflow.
The Air Compressor Pump and shroud are designed to allow
for proper cooling.The ventilation openings on the
compressor are necessary to maintain proper operating
temperature. DO NOT place rags or containers on or near
these openings. Keep the Air Filter clear of obstructions that
could reduce airflow to the air compressor.
Operate the air compressor with unit located on a flat
surface to ensure that it receives proper lubrication.
If you have any problems with operation of your air
compressor, call air compressor helpline at 1-800-743-4115.
If calling for assistance, please have the model, revision, and
serial number from the data tag available.

Grounding Instructions

1.
The cord set and plug supplied with this unit contains a
grounding pin.This plug MUST be used with a grounded
outlet.
WARNING
Improper grounding can result in electrical shock.
use grounding adapters
• DO NOT
Do not modify the plug provided. If it does not fit the
available outlet, a qualified electrician should install a
proper outlet.
A qualified electrician MUST make repairs to the cord set
or plug.
2.
Make sure power outlet being used has same
configuration as air compressor's plug (see Figure 4).
DO NOT use a ground adapter.
Figure 4 - Correctly Rated 15 AMP Power Duplex Outlet
8
.
3.
Inspect plug and cord before each use. DO NOT use
compressor if there are signs of damage.
IMPORTANT: If these grounding instructions are not
completely understood, or if in doubt that air compressor is
correctly grounded, have installation checked by a qualified
electrician.
Starting Your Air Compressor
1.
Make sure ON - OFF switch is in OFF position.
2.
Plug power cord into grounded 120 Volt A.C. outlet
(see Figure 4).
3.
Turn PRESSURE CONTROL knob counterclockwise until
knob turns without resistance (see Figure 5).
Figure 5 - Pressure Control Knob and ON - OFF Switch
Pressure Control Knob
ON - OFF Switch
4.
Pull ON - OFF switch to ON position. Compressor will
start.
NOTE: If the motor fails to start, refer to
TROUBLESHOOTING on page 16.
NOTE: If you hear air leaking, pull quick connect coupler
back until it clicks to reset coupler valve.
The air compressor is fully automatic and is controlled by the
pressure switch.The compressor will run until pressure in the
air tank reaches cut-out pressure.The compressor will restart
when pressure in the air tank falls below the cut-in pressure.
See GLOSSARY on page 18 for definitions.
NOTE: Always operate the air compressor in well-ventilated
areas free of gasoline or other flammable/combustible vapors.
If the compressor is being used to spray volatile chemicals
(such as paint), locate the compressor at least 20 feet
(6.1 meters) away from the spray area.
Tabla de contenido
loading

Este manual también es adecuado para:

074000

Tabla de contenido