SOMFY Tilt Only 50 RTS Central Manual página 20

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
EN
2.2. WIRING
Danger
• Cables which pass through a metal wall must be protected and
isolated using a sheath or sleeve.
• Attach cables to prevent any contact with moving parts.
• The drive cable cannot be removed. If it is damaged, return the
drive to the After-Sales department.
• To ensure electrical safety, this class III drive must be powered by
a "SELV" voltage source (Safety Extra Low Voltage).
Attention
• Leave the drive power supply cable accessible: it must be
possible to replace it easily.
• Do not disconnect the battery or power supply while the drive
is working.
Connect the battery or power supply to the drive's
power supply cable.
2.3. COMMISSIONING
͉
The orange LED flashes continuously in setting mode.
͉
The green LED flashes once when any order is received from a control point.
2.3.1. Pre-programming the RTS control point
Press the Up and Down buttons on the RTS control
point simultaneously: the motorised product
moves up and down and the RTS control point is
pre-programmed in the drive.
20
Copyright
2021 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
Tilt Only 50 RTS Central Pack