Fulgor Milano FHH 600 ID TC BK Instrucciones Para La Instalación Y El Uso página 46

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 124
4 - OPERATION
EN
4.1 DESCRIPTION OF THE EXTRACTOR
INDUCTION HOB
4.1.A TECHNICAL FEATURES
Power level detail:
The total power limitation (Power Limitation, see Operation
paragraph) when the heaters operate simultaneously can be
configured according to the following values:
2800W - 3000W - 3680W - 4000W - 4500W - 5000W -
6000W - 7400W
Parameters
Multi-phase connection voltage
Mono-phase connection voltage
Frequency
Max absorbed power
Fuse / connection to the three-phase network
Fuse / connection to the bi-phase network
Fuse / connection to the mono-phase network
Dimensions (width x depth x height)
Net weight (hob only)
Gross weight (complete with packaging)
Hob
Surface material
Power level
Cooking zone dimensions
Min-max level (booster) cooking zone power
Hob energy consumption (pot dimensions)
Left front cooking zone (FL) (?)
Front right cooking zone (FR) (?)
Rear left cooking zone (RL) (?)
Rear right cooking zone (RR) (?)
Total (on average)
Extraction system
Power level
Recirculating air filter
Ceramic filter regeneration duration
14
Fig. 24
Value
380 – 415V 2N / 3N
220 – 240V
50Hz / 60Hz
7.4 kW
3 x 16A
2 x 16A
1 x 32A
60cm. 600 x 520 x 255mm
80cm. 800 x 520 x 255mm
60cm. 19.0 kg. / 80cm. 20.0 kg.
60cm. 27.5 kg. / 80cm. 29.5 kg.
Glass-ceramic
1 - 9, P
OCTA 210 x 190mm
700W-2100W (3000W)
187.3 Wh/Kg
187.3 Wh/Kg
187.3 Wh/Kg
187.3 Wh/Kg
187.3 Wh/Kg
1 - 9, P
120 hours
loading

Este manual también es adecuado para:

Fhh 800 id tc bk