Hansgrohe ShowerTablet Select 300 13151 Serie Instrucciones De Montaje página 4

Ocultar thumbs Ver también para ShowerTablet Select 300 13151 Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
Safety Notes
� Gloves should be worn during installation to prevent crushing and cutting
injuries.
� The product may only be used for bathing, hygienic and body cleaning
purposes.
� Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this product.
� The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no
weak points.
• The product is not designed to be used with steam baths!
• If the water connections are not stabil mounted, the fitting must be fixed with
2 to 4 extra screws. (see page 32, Fig. A1 - A11) With this type of installation,
take care not to puncture the water pipe! If the water connections are stabil
mounted, no extra screws are required (see page 33, Fig. B1 - B11)
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Centre distance:
Connections G 1/2:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 35)
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
Fault
Insufficient water
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
Spout temperature does not correspond with
temperature set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
Shower or spout dripping
4
English
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
• The check valves must be checked regularly according to EN 806-5 in
• To guarantee the smooth running of the thermostat, it is necessary from time to
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
150±12 mm
cold right - hot left
70°C / 4 min
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't removed
- Dirt or sedimentation on valve seat, shut-off unit
damaged,
Assembly (see page 32)
Adjustment (see page 34)
Maintenance (see page 36)
accordance with national or regional regulations (at least once a year).
time to turn the thermostat from total hot to total cold.
Dimensions (see page 38)
Flow diagram (see page 38)
Shower outlet
Bath Spout
Spare parts (see page 39)
XXX = Colors
000 = Chrome Plated
400 = White/Chrome Plated
Cleaning (see page 40)
Dismounting (see page 34)
Operation (see page 40)
Test certificate (see page 39)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 60 ºC
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
- Exchange shut-off unit
loading

Este manual también es adecuado para:

Showertablet select 300 13171 serie