Urmet 1083-003D Manual De Instrucciones página 3

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
The column interface Ref. 1083/50 is designed
for the 2Voice system. It is used to split a column
into several backbones or to connect several
independent columns (max 32) in the system. It can
manage one column or up to two calling stations
directly connected to it.
Refer to the information contained in the system
booklet supplied with the power unit Ref. 1083/20
for possible system confi gurations.
INSTALLATION
The column interface can be installed in an
electrical panel on a DIN bar (it occupies ten 18mm
DIN modules) or wall-mounted using bolts (not
included). The terminal boards can be accessed
when the electric panel is open.
DESCRIPTION OF TERMINALS
]
Z
Line termination
]
LINE IN
Line in
]
LINE OUT Line out
]
IN0
Calling station
]
IN1
Calling station
Column line power and
]
POWER
calling stations
]
AUX
Door opening output
]
LINE 1
Column, backbone 1
]
LINE 2
Column, backbone 2
]
LINE 3
Column, backbone 3
]
LINE 4
Column, backbone 4
CONFIGURATION
ON
1
Default settings:
DIP 1= ON
DIP 4= OFF
DIP 2= OFF
DIP 5= OFF
DIP 3= OFF
DIP 6= OFF
DIP 1: set to OFF if devices are connected to LINE
DS1083-003D
All manuals and user guides at all-guides.com
2
3
4
5 6
IN.
IN 0
ON
IN 1
1
1
LINE IN LINE OUT
Not connected
DIP 2 - 6: these switches are used to program the
column code and must be set according to the
table shown in the system booklet supplied with
the power unit Ref. 1083/20.
LINE TERMINATION SETTINGS
The Z default terminals are reciprocally short-
circuited. Remove the jumper to cut out the line
termination. The termination must be activated in
all devices arranged at the end of a line, i.e. when a
line is present on LINE IN and not on LINE OUT.
Z= OFF
LINE IN
LINE OUT
1083/50
From main calling station
or call module interface
AUX TERMINALS
These contact terminals close for 1 second
whenever the interface receives a door opening
command by pressing the
apartment station of its column.
TECHNICAL SPECIFICATIONS
Power voltage (POWER IN):
Power voltage (POWER):
Stand-by consumption (LINE IN):
Max. consumption (LINE IN):
Stand-by consumption (POWER):
Max. consumption (POWER):
Working temperature range:
Reference standards:
AUX Max commutable charge:
IN 0
IN 1
LINE IN LINE OUT
From main
calling station or
other column interface
Z= OFF
LINE IN
LINE OUT
LINE IN
button on an
36 – 48 Vdc
36 – 48 Vdc
25 mA max
70 mA max
30 mA max
100 mA max
- 5 ÷ + 45 °C
EN 61000-6-3,
EN 61000-6-1
100 mA@60V
ON
Z= ON
3
loading

Este manual también es adecuado para:

1083