S&P BR 25 Manual De Instrucciones página 33

Idiomas disponibles

Idiomas disponibles

Declaration of performance heat recovery unit BR 25 PLUS E
Supplier name or trade mark
Supplier Model Identifi er and options installed
Reference climate
SEC in [kWh/(m²a)] per ogni tipo di clima (temperato,
caldo, freddo)
SEC Class
Declared Typology
Type of drive installed
Type of heat recovery
Thermal effi ciency¹
Maximum fl ow rate in [m³/h]²
Maximum electric Power in [W]
Sound Power Level (LWA) in [dB(A)]³
Reference fl ow rate [m
/h]
³
4
Reference pressure difference in [Pa]
SPI in [W/m
/h]
³
5
Control factor and typology
Declared maximum internal leakage [%]
Declared maximum esternal leakage [%]
Effi ciency according EN13141-7:2010 at reference fl ow at 50 Pa;
1
Maxiumum fl ow at 100 Pa external pressure;
2
Casing radiation at reference fl ow rate at 50 Pa external pressure;
3
Reference fl ow rate is 70% of maximum fl ow at 50 Pa external pressure according EN13141-7:2010;
4
5
According EN13141-7:2010 at reference fl ow rate;
According EN13141-7:2010;
6
SEC: Specifi c Energy Consumption.
S&P
BR 25 PLUS E + 4BRF
Temperate Cold
-31,28
-64,63 -9,54
A
A+
UVR-B Bidirectional
Multi-speed drive
Recuperative
73,3%
250
114
50
175
50
0,28
1
0,7
6
1,5
6
S&P
BR 25 PLUS E +
RHRF / CO2RF
Hot
Temperate Cold
Hot
-34,98
-69,56 -12,55
E
A
A+
E
UVR-B Bidirectional
Variable speed
Recuperative
73,3%
250
114
50
175
50
0,28
0,85
0,7
1,5
S&P
BR 25 PLUS E +
RHRF / CO2RF local
Temperate Cold
Hot
-39,32
-75,52 -15,95
A
A+
E
UVR-B Bidirectional
Variable speed
Recuperative
73,3%
250
114
50
175
50
0,28
0,65
0,7
1,5
33