VOLTAGE AND CIRCUIT PROTECTION
Refer to the specification chart for the voltage and minimum branch circuit require-
ments.
Certain air compressors can be operated on a 15 amp circuit
if the following conditions are met.
1.
Voltage supply to circuit must comply with the National Electrical Code.
2.
Circuit is not used to supply any other electrical needs.
3.
Extension cords comply with specifications.
4.
Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse.
NOTE: If compressor is connected to a circuit protected by fuses, use only
time delay fuses. Time delay fuses should be marked "D" in Canada and "T"
in the US.
If any of the above conditions cannot be met, or if operation of the compressor
repeatedly causes interruption of the power, it may be necessary to operate it
from a 20 amp circuit. It is not necessary to change the cord set.
kNOW YOUR AIR COMPRESSOR
READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR
UNIT. Compare the illustrations with your unit to familiarize yourself with the location
of various controls and adjustments. Save this manual for future reference.
Tank
Pressure
Gauge
Safety Valve
Power Cord
Nozzles to be used
with the High Flow
inflator/Deflator
adapter body
High Flow
Inflator/Deflator
Adapter Body
OPERATION
Regulator
Tapered
Thread Seal
Nozzles
Tape
11 - ENG
Off (O)/Auto (I)
Switch
Outlet
Pressure Gauge
Air Outlet
Hose
Adapter
Inflation Needle
Air Hose
Female Air
Chuck