Tecnotest 3167 Manual Operativo página 49

Prueba baterias
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 135
________________________________________________________________________BATTERY TESTER
4. Press the GO key. This displays the Select Units screen.
5. Use the Down Arrow key to select a capacity rating for the test.
The two asterisks ( **
NOTE:
This is the battery's capacity rating that is usually found on the battery's label.
Depending on the battery, use any of the following:
CCA - cold cranking ampere rating.
CA / MCA - cranking ampere / marine cranking ampere rating.
A-HR - ampere hours.
DIN - German-Duetche industry norm.
JIS - Japanese industrial standard.
6. After selecting a capacity rating, press the GO key. This displays a screen for
entering the capacity rating.
7. Use the Up and Down Arrow keys and adjust the rating until it matches the
rating on the battery's label.
NOTE:
Do not use the rating reported by the tester because it is typically higher than the
printed rating for a newer battery.
8. Press the GO key to begin the load and recovery part of the test. The screen
displays First Load On, Second Load On, Recovery Period, and then
Working as it applies two medium loads to the battery followed by recovery
periods and then determines the battery condition.
NOTE:
If the tester senses abnormal conditions, such as a cold battery, other screens may
display. Respond to any questions as necessary.
OPERATING INSTRUCTIONS
SELECT UNITS
>
CCA
**
CA/MCA
>
) indicate the selected line.
SET
CCA= 600
'GO' TO ACCEPT
A-HR
DIN
JIS