Installation (continued)
DOOR POSITION ADJUSTMENT
If the doors need to be repositioned, the hinges can be adjusted to
ensure a precise fit with the cabinet.
1 . The lateral adjustment screw adjusts the door orientation from
left to right .
2 . The horizontal adjustment screw adjusts the door orientation
from front to back .
3 . The vertical adjustment screw adjusts the orientation
up or down .
INSTALLING THE FAUCET
- Connect the sprayer head (1) to the sprayer head connector (2) .
- Remove the gasket (3), metal washer (4), and retaining nut (5)
from the faucet .
- Install the faucet through the hole in the sink .
- From underneath, secure the faucet to the sink with the gasket
(3), metal washer (4), and retaining nut (5) .
- Tighten the retaining nut (5) by hand until it is snug . Use a
wrench to tighten it down . Gently tighten the two screws on the
retaining nut . Do not overtighten .
- Hand-tighten the hose (6) to the faucet outlet (7) . Tighten the
fittings using two wrenches. Hold the faucet outlet (7) steady
with a wrench while turning the hose fitting with another
wrench until it is snug .
NOTE:
Failing to use two wrenches can damage the faucet. Do not
overtighten.
- Push the sprayer head (1) into the faucet neck . Install the
counterweight (8) a couple of inches from the bottom of the
hose on the side closest to the sprayer head (1) . There should
be no slack in the hose and it should retract freely .
- Connect the water supply lines (not supplied) to the faucet .
- This faucet is equipped with standard 1/2" NPS male thread
connectors that are compatible with standard 1/2" FIP water
supply lines .
Faucet body
Gasket (3)
Retaining nut (5)
Faucet outlet
7
1
3
Sprayer head
connector (2)
Sink
Metal Washer (4)
Screws
Faucet outlet (7)
Hose (6)
Counterweight (8)
Water Connectors
1/2" NPS thread
Hose
1/2" FIP water supply
line compatible
(not supplied)