DMH - DMH_C - DMV
9.
ELECTRICAL CONNECTIONS
B E F O R E
S T A R T I N G
OPERATION, MAKE SURE THAT THE
MAIN POWER SUPPLY LINE HAS
BEEN ISOLATED
P E R F O R M T H E C O N N E C T I O N S
WITH CABLES FEATURING CABLES
FEATURING A SUITABLE CROSS-
SECTION
•
The electric connections to the
control board must be made by
specialised staff according to
the diagram supplied.
•
Make sure that the voltage and
the frequency stated on the
plate correspond with those of
the electric connection line.
•
The use of adapters, multiple
s o c ke t s a n d /o r ex t e n s i o n s
is not allowed to power the
dehumidifier.
•
It is the installer's responsibility
to assemble the unit as near as
possible to the power supply
isolator and the necessary to
protect the electric parts.
•
Connect the unit to an efficient
earth socket, using the relevant
screw inserted in the unit itself.
•
Use the cable gland (external
for horizontal versions, internal
for the recessed version) near
the panel to turn it on.
CONNECTION
TYPE I/O
S01 - GND
Analog input
S02 - GND
Analog input
ID1 - GND
Digital input
ID2 - GND
Digital input
ID3 - GND
Digital input
ID4 - GND
Digital input
R01 - GND
Digital output
R02 - GND
Digital output
R03 - GND
Digital output
R07 - GND
Digital output
(*) the installer is responsible for any external circuit
(**) The contact in question is normally open and closes in the event of an alarm on the unit: can be connected, for example, as a consensus for powering on
a LED alarm signal.
A N Y
FORCED AIR HEATER MODE ON/OFF
ON/OFF MODALITA' TERMOVENTILANTE
POTENTIAL FREE CONTACT
VENTILATORE
MEANING I/O
Water input temperature
Inlet air temperature
High pressure switch
Low pressure switch
Humidistat consent
Forced air heater mode On/Off
Compressor consent
Alarm circuit (230 V) (*)
Fan consent
Set-up (potential free contact)(**)
GND
WATER PROBE
SONDA ACQUA
[S01]
GND
AIR PROBE
SONDA ARIA
[S02]
S02
GND
HUMIDISTAT
[ID3]
UMIDOSTATO
TIMER
GND
[ID4]
RES
GND
LOW PRESSURE
BASSA PRESSIONE
[ID2]
BP
GND
HIGH PRESSURE
ALTA PRESSIONE
[ID1]
HP
GND
[R07]
CONTATTO PULITO
INT
PER ALLARME
FOR ALARM
ALL (230V)
[R02]
Common
Comune/Common
White
FAN
Bianco
min
min
Red
Rosso
[R03]
average
med
Blue
Blu
max
max
Black
Nero
COMPRESSOR
COMPRESSORE
[R01]
230 V / 50 Hz/ 1 ph
HP pressure switch status
BP pressure switch status
Dehumidifier status
Thermoventilating state
Compressor status
Circuit alarm status
Fan status
Circuit alarm status
EN
S01
250mA
230 V
P
STATE I/O
Probe reading S01
Probe reading S02
0 = Closed
1 = Open (Warning)
0 = Closed
1 = Open (Warning)
0 = Off
1 = On
0 = Off
1 = On
0 = Off
1 = On
0 = Absent
1 = current
0 = Off
1 = On
0 = Absent
1 = current
27