Stihl MS 360 Manual De Instrucciones página 37

Idiomas disponibles

Idiomas disponibles

english
In the warm start position, continue
cranking after the engine begins to
fire. As soon as the engine runs,
immediately blip the throttle trigger
so that the Master Control lever moves
to the run position # (3).
To shut down the engine:
Move the Master Control lever upward to
the stop position $ (4):
The stop contact engages the contact
spring – this cuts out the ignition
system.
36
Starting / Stopping
the Engine
Only machines with
decompression valve
:
Press in the button (arrow) to open
the decompression valve.
The valve closes automatically as soon
as the engine begins to fire.
For this reason the decompression valve
should be pressed in before each
starting attempt.
0
1
All versions
:
Observe safety precautions - see
chapter "Safety Precautions".
:
Push hand guard (1) forward:
The chain is now locked.
:
Press down trigger interlock (2) and
squeeze throttle trigger (3) at the
same time.
Set Master Control lever to:
for cold start l
for warm start n
(even if engine has been running
but is still cold).
STOP
2
3
MS 360
loading