To replace the battery:
•
The booster must be disconnected from the power supply.
Then, unscrew the back panel (picture 1 1 - 8 screw) and remove it.
•
•
The battery is stabilized in the GYSPACK by a battery holder. Loosen the 2 screws located on the front wall so that
the battery can be removed (illustration 2 ) .
•
Once this has been done, the front of the battery is visible (see picture). The battery is connected to the GYSPACK
at two points: at the - terminal (picture 3 ) and at the + terminal (picture 4 ). To remove the battery, remove the
2 nuts that enable the connection between the battery and the GYSPACK at the + and - terminals.
When putting a new battery in, make sure to match the polarities of both the battery and the
GYSPACK PRO 700/900. - Terminal on the left, + terminal on the right (see picture). Put the 2
screws and washers back on, tighten the nuts (recommended tightening torque of 4 Nm).
•
Tighten again the partition and screw the back panel back on.
GYSPACK PRO 700 / 900
Type
Lead acid battery
PC950
Lead acid battery
Voltage (V)
Capacity (Ah)
12
16
12
30
EN
Dimensions
Battery ref
(cm)
18 x 8 x 17
53131
25 x 9,7 x 15,6
53135