SHUTDOWN
1. Remove all load by turning off electrical appliances and
unplugging electric cords.
2. Allow engine to run at idle speed (3000), or at no load condition
(3000-1MH0, 4000, 5000) to cool for two (2) minutes.
NOTE: Failure to allow the engine to cool for two (2)
minutes may result in damage to the generator.
3. Turn engine key or ignition switch off.
4. Close fuel valve on unit or engine.
CONTROLS
CONTROL PANEL:
The generators are equipped with the following items:
3000 w units:
-
Circuit Breaker
-
One 125 Volt, 20 Amp, GFCI protected receptacles.
4000 w and 5000 w units:
-
Full Power Switch
-
Circuit Breakers
-
Two 125 Volt, 20 Amp, Duplex (2 outlets), GFCI protected
receptacles.
-
One 125 Volt, 30 Amp, Locking Type Receptacle.
-
One 125/250 Volt, 20 Amp, Locking Type Receptacle.
NOTE: The 125 Volt, 30 Amp locking receptacles ARE NOT
GROUND FAULT PROTECTED. If ground fault protection
on these receptacles is necessary or desired, external
protection devices must be used. Refer to the section on
"Ground Fault Interrupter" for more information.
WARNING:
NEVER
A
RECEPTACLE.
PROTECTED AGAINST OVERLOADS BY RESETTING
MAGNETIC
TYPE
CIRCUIT BREAKER TRIPS, THE CAUSE SHOULD
BE DETERMINED AND CORRECTED PRIOR TO
CONTINUING USE.
Operator's Manual
Operating the Generator
EXCEED
THE
RATING
THESE
RECEPTACLES
CIRCUIT
BREAKERS.
OF
ARE
IF
A
21
loading