Operation
3. In the basic menu, use the cursor keys  or  to select "Short
selection":
4. Press ENTER to confirm.
5. Use the keypad (8) and the cursor keys to enter the vehicle data.
6. Press ENTER to confirm.
7. Enter the refrigerant filling quantity. Use the value shown on the
filling quantities sticker in the vehicle and enter it using the keypad
(8) and the cursor keys and press ENTER.
8. Use the cursor keys  or  to select whether the air conditioning
system has two°connections (high pressure and low pressure) or
only one connection (high pressure or low pressure).
Press ENTER to confirm.
✓ The fully automatic air conditioning service is started.
The refrigerant is analysed during the air conditioning service (see
chapter "Analysing refrigerant" on page 94).
✓ After the air conditioning service has finished, you will be prompted to
disconnect the hoses (13) and (14) of the AirConServiceCenter from
the vehicle air conditioning system.
9. Disconnect the service hoses (13) and (14) and press ENTER to
confirm.
The service hoses will now be drained. The unit is then ready for
further use.
10. Put the valve caps of the vehicle air conditioning system back on the
connections.