6. USE OF THE ECO HOT WATER
INTELLIGENT MODE
The INTELLIGENT operating mode retains all the functionality of ECO-
HEATING, plus the automatic integration of the electric heater depending
on the room temperature (AT):
- If AT>20°C = heat pump operation only
- If 5°C < AT < 20°C = integration of the electric heater with the delay
time that can be set in parameter r06.
- If AT < 5°C = immediate integration of the electric heater.
Electric heater
Electrical resistance with delayed start (delay=par.r06)
Heat pump
HOLIDAY MODE
This mode can be used when you do not want to heat the water for a few
days (for example during a holiday period). The date of activation must be
set after the unit has been switched OFF.
Hold the
key for 2 seconds to enter into the timer interface.
The symbol "ON" and the DATE flash. Set the day and month in which you
want the unit to turn on.
Leaving the unit in holiday mode and in the OFF position, the unit will
restart on the set day and month.
If after you have set the date of reactivation, the unit is not left switched
off (OFF) and in holiday mode, the function HOLIDAY is not enabled.
For example: today, the 20th August the unit is left in holiday mode and
OFF, and on the 28the September, the unit will restart automatically.
To clear the date set for the holiday mode, when the month and ON
flash, press the key
EN
EN
57