Name
This parameter enables the user to assign the automation with a name other than the original, to facilitate identification (e.g.
"northern gate").
A name comprising maximum 24 characters, including spaces, is admitted.
Series
This parameter can be set with a value from 0 to 63; the factory setting is "0".
The series is a number that has to be assigned to each gearmotor, receiver or other device potentially connectable on a BusT4
network, to define its "classification area", Subsequently, when using the automations in a complex system, all devices with the
same assembly number can be controlled simultaneously.
Address
This parameter can be set with a value from 1 to 127; the factory setting is 3.
The address is a number that has to be assigned to each gearmotor, receiver or other device potentially connectable on a
BusT4 network, to distinguish it from other devices in a series. Therefore all devices within a series must have a different
address from one another.
Group
This parameter can be set with a value from 0 to 15; the factory setting is "0". The function enables the user to assign a num-
ber to a device to be controlled (for example a gearmotor or other device potentially connectable to a BusT4 network), which
enables this device to belong to a specific "command group". Several devices, also if belonging to different Series, can form
part of the same group. Up to 14 groups of devices can be created and, in particular, the same device may be inserted in 4 dif-
ferent groups.
In a device network, use of this function enables:
- simultaneous control of different devices inserted in a group, even if some of these belong to different series;
- use of a single receiver, installed in one of the devices bonging to the group, to control all the devices belonging to this group.
Firmware version (not modifiable)
This function enables the display of the version of the firmware present in a device.
Hardware version (not modifiable)
This function enables the display of the version of the hardware present in a device.
Serial number (not modifiable)
This function enables the display of the serial number identifying a specific device. This number is different for each device, even
if the same model.
Password management
This function is useful to restrict access by unauthorised personnel to all or some of the programming functions of a device. If
a device is password protected, the user must perform the "log in" procedure to proceed with a programming session, followed
by the "log out" procedure at the end of the session. Note – the "log out" procedure enables the user to prevent access by
unauthorised personnel, by re-activating the existing password. Caution! – When programming the password on several
devices (for example in Oview, the Control unit, Receiver etc.), we recommend using the same password for all devices,
including Oview. This will avoid the need to repeat the login procedure each time the device is changed during use of Oview
and the connected Software.
Two types of password can be programmed on the devices (including Oview).
- the user password, comprising maximum 6 alphanumeric characters. Caution! – Do not use uppercase letters.
- the installer password, comprising maximum 6 alphanumeric characters. Caution! – Do not use uppercase letters.
COMMON FUNCTIONS