Emerson AVENTICS AF2 Instrucciones De Servicio página 39

Ocultar thumbs Ver también para AVENTICS AF2:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
Connection type
Output signal
Output load
Lower signal level
Upper signal level
Digital output
Power consumption
Signal voltage HIGH
Signal voltage LOW
Inductive load
Capacitive load
2)
All connections are protected against reverse polarity and are overcurrent-proof. Q1, Q2,
and Qa are short-circuit-resistant.
3)
Configuration of the digital output: PNP/NPN/push-pull.
Pneumatics
Table 17: General data
Medium
Process temperature
Process pressure
Table 18: Data for AS-AF2 variant
Process connection
Table 19: Data for HF-AF2 variant
Process connection
Storage
Ambient temperature for storage
Standards and directives complied with
Standard/directive
EMC directive 2014/30/EU
DIN EN 61326-2-3
14 Spare parts and accessories
Information on spare parts and accessories can be found in the online catalog.
Description
Connecting cable, CON-RD, M12x1 series
AVENTICS™ AF2 | R412026496–BAL–001–AB | English
Specifications
M12x1 round plug, 5-pin A-coded
• 1 x analog output 4 ... 20 mA or 1x digital
switch output / pulse, frequency output
configurable
• 1 x analog output 4 ... 20 mA or 1x digital
3)
switch output (configurable)
4 ... 20 mA, 500 ohms if U
> 15 V
V
3.5 ... 3.8 mA
20.5 ... 21.5 mA
≤ 100 mA per output
< 12 W (@ 24 V DC without output load)
> U
 ... 2 V
V
≤ 2 V
1 H
100 nF (2.5 nF in IO-Link Mode)
Specifications
• Compressed air (air quality as per
ISO 8573-1:2010 [3:4:4])
• Helium, argon, nitrogen, carbon dioxide
-20 ... +60 °C
0 ... 16 bar
Specifications
G3/8", G1/2", G1" (in accordance with
DIN ISO 228-1)
Specifications
• DN40: R1 ½ or 1 1/2" NPT
• DN50: R2 or 2" NPT
Specifications
-40 ... +85 °C
Description
Electromagnetic compatibility of electric
products and electronic products
Interference emission and interference im-
munity
Item no.
R412027647
39