Emerson AVENTICS AF2 Instrucciones De Servicio página 34

Ocultar thumbs Ver también para AVENTICS AF2:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
Objective
Submenu
Set the port
Port
Reset the user-defined pass-
ResetPW
word
Webserver
State
Port
ResetPW
Fig. 21
OPC UA
Objective
Submenu
Switch the web interface on
State
and off
Set the port
Port
Set the user name
User
Assign a password
Password
OPC UA
State
Port
User
Password
Fig. 22
MQTT
Objective
Submenu
Switch the web interface on
State
and off
Broker
Broker
Set the port
Port
Topic
Topic
User
User
Create the broker password
Password
Send the update interval to
Update
the broker
QoS
QoS
Define MQTT message to the
Send
broker
AVENTICS™ AF2 | R412026496–BAL–001–AB | English
Option
Select the web server port.
The default port for the HTTP
service is port 80
Reset the web server pass-
word for the "Maintenance"
user to factory default. The
default password (factory set-
ting) is "airflowsensor"
Active
Inactive
abort
store
#####
abort
store
(action required)
abort
store
Option
Select between Active and In-
active
Set the port
Set the user name
Set the password
Active
Inactive
abort
store
#####
abort
store
# ... #
abort
store
# ... #
abort
store
Option
Select between Active and In-
active
Set the broker
Set the port
View the topics
Enter a user name for the bro-
ker
Enter the broker password
Set the update interval
Select QoS-0, QoS-1, or QoS-2
Select a menu item from the
second submenu and set to
Active or Inactive
MQTT
State
Broker
Port
Topic
User
Password
Update
QoS
Fig. 23
Send
Fig. 24
8.4.3 Settings for the IO-Link variant
The settings apply to all variants of the flow sensor with IO-Link electrical connec-
tion.
IO-Link
The display shows the measured value menu with the default setting (kg/h, m/s).
Objective
Menu
Select menu
Standard screen
Set the switch output
Q1 Menu
Set the switch output
Q2 Menu
Active
Inactive
abort
store
### ### ### ###
abort
store
#####
abort
store
######/#/####
abort
store
######
abort
store
######
abort
store
##### ms
abort
store
QoS0
QoS1
QoS2
abort
store
Unit
Active
Inactive
abort
store
MassFlowRate
Active
Inactive
abort
store
FlowVelocity
Active
Inactive
abort
store
VolFlowRate
Active
Inactive
abort
store
Volume
Active
Inactive
abort
store
Mass
Active
Inactive
abort
store
Energy
Active
Inactive
abort
store
Temperature
Active
Inactive
abort
store
Pressure
Active
Inactive
abort
store
AdditInfos
Active
Inactive
abort
store
AppStatistic
Active
Inactive
abort
store
Option
Press and hold any arrow but-
ton for at least 2 seconds and
select between Q1 Menu,
Q2 Menu, and Qa Menu.
Set the switch output
Set the switch output
34
loading