Commissioning the DGMa
Figure 4
Replacing/adding modules
Page 28
IMPORTANT
• All of the arrows on the modules must point in the same direction.
• If the modules cannot be screwed in easily, start again.
If you do not, the connection will not be sealed properly and you will not be
able to separate the modules again without damaging them.
Turn the module clockwise until it is straight upside down
If a larger mounting panel is required, move the clamps
Press the new module block into the mounting panel clamps
Close the outlet nozzle or the sampling tap
If it has been removed, screw the mounting panel back onto the wall
Screw in the sensors and, if necessary, calibrate them (please refer to the sensor operating
manuals)
Connect the hoses of the in-line probe housing
Open the ball valve and, if there is one, the stop valve on the out-flow side slightly
Check that the modules are sealed properly
Set the flow
1. Attach the module (front view)
2. Turn it clockwise (side view)
3. Ready (front view)
3075-3