Connecting order
• Connect the terminal block in following order.
Power supply
Terminal block for
indoor/outdoor unit
<Case1> Connecting with Cylinder unit / Hydrobox / DHW tank
Connect the Cylinder unit / Hydrobox / DHW tank to Room A only. "*1" below
Also, use a separate power source to power the Cylinder unit / Hydrobox / DHW tank. "*2" below
Indoor/outdoor unit
connecting wire
Terminal block
Terminal block for power supply
Terminal block
<Cylinder unit /
Hydrobox / DHW
tank>
POWER SUPPLY
~/N 230 V 50 Hz *2
• Be sure to attach each screw to its correspondent terminal when securing the cord and/or the wire to the terminal block.
• Make earth wire a little longer than others. (More than 35 mm)
• For future servicing, give extra length to the connecting wires.
<Case2> Connecting without Cylinder unit / Hydrobox / DHW tank
Indoor/outdoor unit
connecting wire
<OUTDOOR UNIT>
B
Terminal block
Terminal block
Terminal block
Terminal block
B
<ATA INDOOR UNIT>
PXZ-5F85VG
<OUTDOOR UNIT>
B
E
*1
Terminal block for
power supply
Terminal block
POWER SUPPLY
~/N 230 V 50 Hz
Terminal block
B
E
<ATA INDOOR UNIT>
Terminal block for
power supply
POWER SUPPLY
~/N 230 V 50 Hz
A → B → C → D → E → P
15 mm
35 mm
Lead wire
INDOOR /
Model
OUTDOOR UNIT
A – E
PXZ-5F85VG
This tap mark indicates the Cylinder unit /
Hydrobox / DHW tank connection side for the
following parts.
• Terminal block for the connecting
cables, S2/S3 (cannot connect to S1)
• Stop valves, gas and liquid for the
refrigerant connection