Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water, swivel to the right =
cold water.
38400XXX/38401XXX: The flow is changed from
bath to shower function by pulling the diverter knob.
After shutting off the water flow, the mixer returns
automatically to the bath function.
Technical Data
Operating pressure:
Recommended operating pressure: 0,1-0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G ½":
Rate of flow 0,3 MPa:
Back flow and vacuum breaker
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work - Flow limiter in handshower isn't
6
English
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Hansgrohe single lever mixers can be used tog-
ether with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
Spare parts
1 handle
1.1 screw cover
2 flange cpl.
3 nut
4 cartridge cpl.
5 escutcheon
6 S - unions
7 aerator cpl.
8 selector
max. 1 MPa
9 diverter knob
10 non return valve
1,6 MPa
11 noise reduction
12 lever head "Zero"
max. 80° C
65° C
150 ± 16 mm
cold right -
hot left
approx. 22 l/min
Cause
- Shower filter seal dirty
- Non return valve hasn't moved
back
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set - Set hot water limiter
removed
- Filter are dirty
- Non return valve hasn't moved
back
Remedy
- Clean filter seal between shower
and hose
- Exchange non return valves
- Exchange cartridge
- Exchange cartridge
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange non return valves
38091X X X
96338000
96395X X X
96461000
92730000
96467X X X
94140000
13956000
94077000
96466X X X
94074000
96429000
38090X X X