Wiring the HighLighter Elite
HIGH CURRENT DEVICE: A light system is a high current system.
In order for the system to function properly, a separate negative (–)
connection and positive (+) connection must be made. All negative
connections should be connected to the negative battery terminal,
and a 2 A fuse should be installed on the positive battery terminal
connection as close to the battery as possible. Ensure that all
wires and fuses are rated correctly to handle the system amperage
requirements.
The permanent mount HighLighter Elite is supplied with a
12-inch wire harness. The wires must be extended using installer-supplied
18 AWG wire minimum and terminals.
Color
Black
Red
White
Brown
Green
To wire the HighLighter Elite:
1.
Determine the required functions and the length of wires needed
to access them. A five-conductor cable can be selected for a full-
featured installation. For lengths up to 15 feet (5 m), use minimum
18 AWG (1 mm) wire. For lengths over 15 feet, use minimum 16 AWG
(1.5 mm) wire. Before wiring the device, refer to Table 2 for the
function of each wire.
2. Strip 1/4 inch (6 mm) of insulation from the ends of the installer-
supplied wires.
3. Use installer-supplied insulated butt connectors to connect the wires
to the Elite's power cable. Ensure that the connectors are securely
crimped and properly insulated.
Installation, Operation, and Maintenance Instructions
Federal Signal www.fedsig.com
Table 2 Wire Connections
Description
Ground
Mode 1
Mode 2
Low Power/Mode 3
Program/FSLink
Wiring the HighLighter Elite
Connection Point
Battery Negative
Switched Positive
12-24 Vdc
Switched Positive
12-24 Vdc
Switched Positive
12-24 Vdc
12-24 Vdc