RESETTING THE AIR PURIFIER
The air purifier is equipped with a motor protection circut. If activated, the overload warning indicator
will initiate and cut off the power. An audible warning "chime" will sound for 60 seconds. To restart
the unit, unplug the unit for 10 minutes, then plug back in and power on. Note: If the unit continues
to shut down, there may still be an abnormal condition and the unit may need service.
HUMIDIFIER OPERATING INSTRUCTIONS
The humidifier does not operate independent of the air purifier. There are no electricals
controls on the humidifier tank. It uses the air from the purifier exhaust to disperse
moisture into the air.
1. Before using the Humidifier be sure the air purifier is on a firm, level, and flat location.
2. Unplug the Air Purifier.
3. Set the humidifier tank on the top of the air purifier, line it up so that the bottom of the humidifier
tank connects into the top of the air purifier.
4. Remove the humidifier lid and add water to reach the fill line. DO NOT add water above the
fill line (If you prefer, you can fill the tank before placing on the purifier).
5. Replace the lid.
6. Plug in the air purifier.
7. Follow the air purifier instructions.
8. To maximize humidification, set the air purifier to the hightest speed (3).
AIR PURIFIER FILTER REPLACEMENT
The filter reset indicator light will illuminate when it is time to replace your filter. Depending on
usage and environmental conditions the filter will last approximately 6 months. The inside pleats
of the filter will turn from white to grey when it is dirty and needs replacing. It is important to
maintain and change the filter to continue to optimize the performance of the air purifier.
IMPORTANT: Do NOT wash and re-use the filter. Please contact Customer Service or visit our
website www.guardiantechnologies.com to purchase a replacement filter. Use only Genuine
Guardian Technologies replacement parts to optimize the performance of your air purifier.
1. Turn off and unplug the unit.
2. On the back of the unit, pull handle on filter panel and remove panel from unit.
3. Remove filter and disregard. Place new filter into air purifying unit with open end up.
4. Return filter panel, first insert the panel tabs in the base then close. Check that it's secure.
5. Reset the filter light by holding the Timer + Sleep controls down for 3 seconds.
E-6
FILTER REPLACEMENT
IMPORTANT:
Make sure filter is
Open
installed and back
end up
panel is closed
properly, otherwise
unit will not function.