EN
FR
EN
and check that the corresponding LED flashes. Then, select the new time interval for this output. Repeat
this process for as many outputs as you want.
- When you have finished programming, press the START AUTO button to save it. The LED on the
last set output will stop flashing and the TIME display will show a dash.
- Press the START AUTO button to start the switch-on sequence, it will be executed according to the
interval you have set. Press START AUTO again to start the switch-off sequence (the configured intervals
do not apply).
REMOTE MODE
Remote mode allows you to activate the on/off sequence from the contact closure of the connector START
AUTO REMOTE located on the rear panel of the device according to the intervals set in AUTO MODE. To
do this, you must use an RCA connector and install a switch that allows this closing/opening of contacts
(line and shield).
When the equipment detects contact closure, the power sequence of the previously configured outputs
begins, the contacts must remain closed when you want the outputs to remain switched on. When the
contacts are opened, the switch-off sequence begins and they remain off while the contacts are open.
TECHNICAL SPECIFICATIONS
FEATURES
OUTPUTS
INDICATORS
CONTROLS
POWER SUPPLY
DIMENSIONS
Secuencia de encendido
Secuencia de apagado
PD-708
Power sequencer.
Sequential on/off.
Selectable switch-on delay between outputs.
Fixed switch-off delay.
Possibility of remote on/off through contact closure.
8 female schuko connectors, 15 A total
On and auto on/off indicator lights
Selected output indicator light
Delay between devices display
Operating voltage display
Auto on/off
Ignition delay selectors (0.5 to 4.5 s)
Output Selectors
100-240 V AC, 5,000 W maximum
483 x 88 x 180 mm depth. 2 U 19" rack
1
2
1
2
- 4 -
- 4 -
1
2