a) CAUTION! The pre-cooling mode is supported in model RCSI-17/ RCSI-18.
There are two temperature thresholds selectable for the refrigerating system.
First, the low temperature threshold is configured, followed by the high
temperature threshold.
b) CAUTION! When the appliance reaches the low temperature threshold while
running, the refrigerating system will stop.
c)
CAUTION! When the appliance reaches the high temperature threshold, the
refrigerating system will restart.
d) Start the pre-cooling. Do this by pressing and holding the batch pre-cooling /
cooling level selector key (g) for approx. 5 seconds.
e) The control system enters the low temperature threshold setting mode. The
setting can be adjusted to anywhere within 0-10°C.
f)
The LCD reads the current setting of the pre-cooling low temperature
threshold.
g) Change the temperature setting by operating the "SUB" or "ADD" keys (d / e).
h) CAUTION! The user can enter the setting in 1°C increments.
i)
Having input the setting, wait for the appliance to store it in memory and show
the main readings on the LCD.
j)
Do this by pressing and holding the batch pre-cooling / cooling level selector
key (g) for approx. 5 seconds.
k) The control system enters the high temperature threshold setting mode. The
setting can be adjusted to anywhere within 12-25°C.
l)
Enter the setting by repeating step (e) in this section.
3.3.6.
RESETTING THE DISPENSED ICE CREAM CONE COUNTER
a) CAUTION! Resetting the counter too often may cause the electrical circuitry of
the appliance to fail.
b) To display the dispensed ice cream counter reading, press and hold the "SUB"
and "ADD" buttons (d / e) simultaneously for approx. 5 seconds.
c)
Now, press and hold the "SUB" (d) or "ADD" (e) key for 5 seconds. The counter
is reset to zero.
3.3.7.
APPLIANCE OPERATION
a) Fill the refrigerating bin with the ready batch of the product.
b) Keep the batch level between the MIN and MAX marks. Never attempt to
operate the appliance if the batch level is below the MIN mark (the drain port)
or the MAX mark shown inside of the refrigerating bin.
c)
CAUTION! Model RCSI-18 features two refrigerating bins. Load the batch to
both bins to operate this appliance.
d) CAUTION! Do not operate the refrigerating system of this appliance with a
refrigerating bin empty. Risk of failure!
e) Having filled the refrigerating bin with enough of the batch, close the bin with
the lid.