Operation
Control / Lock function
If central controller is connected and central control function is activated, the icon
on the wired controller. As a result, only on/off key of wired controller is available and other keys are
invalid.
If central controller is connected and central controller locked the wired controller, the icon
display on the wired controller. As a result, all keys of the wired controller are invalid.
Forced cooling/ heating function
When the wired controller is off , in cooling mode, hold
cooling function with 'LL' blinking in temperature display area. displaying cooling mode, setpoint
temperature 16°C and high fan speed. After forced cooling function is activated, only
while other keys are invalid. Press
When the wired controller is off , in heating mode, hold
heating function with 'HH' blinking in temperature display area, displaying heating mode, setpoint
temperature 30°C and high fan speed. After forced heating function is activated, only
while other keys are invalid. Press
Forced defrost
When the wired controller is turned on and select heating mode, high fan speed and adjust setpoint
temperature to 30°C (Maximum setpoint temperature when ECO function is activated), press
times in a row within 5s to set forced defrost function. The buzzer sounds 3 times indicates forced
defrost function is set successfully.
for 10s to turn it on and activate forced
to exit forced cooling function and turn off the wired controller.
for 10s to turn it on and activate forced
to exit forced heating function and turn off the wired controller.
10
will display
will
is available
is available
6