Cooper Lighting Solutions PORTFOLIO LDSQ4 Instrucciones De Instalación página 3

Idiomas disponibles

Idiomas disponibles

Installation Instructions – LDSQ4/LDSQ6 Commercial Recessed LED Rough-In
Figure 6
Figure 7
Figure 8
Figure 9
Installation Instructions – LDSQ4/LDSQ6 Commercial Recessed LED Rough-In
IB52009222
Cleaning
To Clean Trims:
1.
Press in on white plastic latch to remove upper
reflector and clean lens. (Figure 10 & 11.)
2.
Gently wipe with soft, clean, dry lint-free cloth to
remove dust.
3.
Wipe with mild detergent solution on a soft, clean
cloth to remove fingerprints and stains.
4.
Rinse with clean water and dry with soft, clean, dry
lint-free cloth.
Plastic Latch
Figure 10
Figure 11
Electrical Connection
Make certain no bare wires are exposed outside of lever nut
connectors.
1.
Provide electrical service according to the "National
Electrical Code" or your local electrical code to the
junction box (located on the plasterframe). Supply
wire insulation must be rated for at least 90°C. The
junction box is listed for (4) #12 AWG (two in, two out)
90°C conductors and feed thru branch wiring for type IC
and Plug in drivers for 120/277V only. For all other
cases (8) #12 AWG (four in, four out) 90°C conductors
and feed thru branch wiring for 120/277V only.
www.cooperlighting.com
White
Upper Reflector
(discard for 2 or 3
LED modules)
Lens
CAUTION
3
loading

Este manual también es adecuado para:

Portfolio ldsq6