Please unfold page 3. Then you can always see the
GB
operating elements and connections described.
1 Operating Elements and Connections
1 Display
2 FM/AM button for switching between the frequency
ranges FM1 (6 FM memory stations), FM2 (6 FM
memory stations) and AM (6 AM memory stations)
3 Button ON for switching the tuner on and off
4 Buttons
and
Pressing the buttons shortly: manual tuning
Pressing the buttons for approx. 2 seconds: auto-
matic tuning
5 Numerical keys for selecting the station memories
6 Volume control (mixing control)
2 Safety Notes
This insertion corresponds to the directive for electro-
magnetic compatibility 89/336/EEC.
The insertion must be installed by skilled personnel
only.
The insertion is suitable for indoor use only. Protect
it against dripping water and splash water, high air
humidity, and heat (admissible ambient temperature
range 0 – 40 °C).
Do not operate the unit and the installed insertion or
immediately disconnect the plug from the mains
socket
1. if there is visible damage to the insertion, the unit,
or the mains cable,
2. if a defect might have occurred after the unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the insertion or the entire unit must be
repaired by skilled personnel.
For cleaning only use a dry, soft cloth, by no means
chemicals or water.
No guarantee claims for the insertion and no liability
for any resulting personal damage or material dam-
age will be accepted if the insertion is used for other
purposes than originally intended, if it is not correctly
installed, operated, or not repaired in an expert way.
If the insertion is to be put out of operation
definitively, take it to a local recycling plant
for a disposal which is not harmful to the
environment.
6
All manuals and user guides at all-guides.com
for adjusting a station
3 Applications
The insertion is suitable for installation in the following
MONACOR units and must be installed in these units
by skilled personnel only.
PA-1120
PA amplifier for 5 zones
PA-1200
PA amplifier for 3 zones
PA-1200EX basic unit for 2 insertions
PA-1204EX basic unit for 4 insertions
PA-1240
PA amplifier for 5 zones
PA-5240
PA amplifier for 5 zones
PA-5480
PA amplifier for 5 zones
4 Installation into the PA Amplifier
WARNING
Prior to the installation of the insertion
disconnect the mains plug of the amplifier
or basic unit of the insertion. Otherwise
there is an electric shock hazard.
1) Remove the cover of the amplifier.
2) Screw off the blank panel of the insertion slot at the
amplifier. Insert the AM/FM tuner and fasten it with
screws.
3) Unscrew the blank panel at the back of the amplifier
and remove it. Insert the supplied PCB with the
antenna screw connections and fasten it with
screws.
4) Only for the amplifier PA-1200: Plug the 2-pole line
of the connection AN08 of the terminals M.O.H. into
the pin jack CON 2 on the PCB of the AM/FM tuners
(see fig. 2).
5) Insert the 3-pole line of the connection AN07 at the
main PCB of the amplifier to the pin socket CON 1
at the PCB of the AM/FM tuner.
6) Insert the 4-pole line of the inserted PCB to the pin
socket CON 3 at the PCB of the AM/FM tuner.
7) The insertion PA-1200R has a storage battery
(position BAT 1) to store the station tunings. This
storage battery is deactivated ex factory to prevent
a gradual discharge prior to the installation. For the
operation activate the battery: Set the switch SW 2
to the right to position ON.
For deactivating the battery for a longer time
(e. g. when storing it), set the switch SW 2 to the left.
8) Always leave switch SW1 in position EUROPE. It
serves to adjust the channel spacing.
9) Connect the reception antennas to the antenna
screw terminals.
AM + GND for AM antenna
FM 75 Ω
for FM antenna with
75 Ω connection cable
300 Ω
for FM antenna with
300 Ω connection cable