5. Remove the right levelling foot and unscrew the two bolts to release the hinge
bracket with the hinge pin. Then unscrew the hinge pin, turn the hinge bracket
over and thread the hinge pin through the hinge bracket and secure with the
nut and locking washer. See Figure 7.
6. Remove the left levelling foot and screw it on to the right side. Refit the hinge
bracket with the hinge pin on the left side making sure the two bolts are
secured tightly into place. Screw the other levelling foot onto the left side. See
Figure 8.
7. Replace the door. Ensure the door is aligned both horizontally and vertically.
This ensures the seals are closed on all sides before you tighten the top hinge.
8. Insert the top-left hinge bracket and secure into place with the two bolts. Make
sure to place the bolts in a diagonal formation as shown. See Figure 9.
9. Put the two covers back on the top of the freezer making sure the larger hinge
cover goes on the hinge on the left-hand side. See Figure 10.