Note: after activating the programming procedure, step 2 can also be carried out by pressing
the button "TC", and from step 3 onwards you may proceed using the opening button "TA".
Attention! If at the end of time programming the LEDs "L2" and "L3" flash simultaneously
the operation was not successful and you will have to repeat the procedure from step 1.

Function mode

• Semi-automatic (Dip 1 = OFF, Dip 2 = OFF)
- automatic reclosing deactivated
- each transmitter channel works as a sequential command.
Open - Stop - Close - Stop.
• Semi-automatic (Dip 1 = OFF, Dip 2 = ON)
- automatic reclosing deactivated
- the transmitter channels have the following functions:
A - Open - B - Close - C - Stop - D - Sequential.
• Automatic (Dip 1 = ON, Dip 2 = OFF)
- automatic reclosing enabled
- the transmitter channels have the following functions:
A - Open - B - Close - C - Stop - D - Sequential.
• Manual mode (Dip 1 = ON, Dip 2 = ON)
- manual operation during closing.
- the closing photocell "FTC" intervenes blocking the motor
- the sequential command has no effect
- the transmitter channels have the following functions:
A - Open - B - Close - C - Stop - D - No function.