INSTALLATION
Important information before installing the appliance
•
Clean the surrounding area thoroughly before and after installation so that no
dust or construction debris can be sucked in during commissioning.
•
Only place the appliance in a suitable location.
•
Check the wall for its load-bearing capacity.
•
Check the routing of electrical and other cables on and in the wall or ceiling so
that they are not drilled into.
•
Check the condition and load-bearing capacity of the electrical cables.
•
Installation of the unit by a specialist is recommended.
•
The extractor bonnet should be installed at a height of 65-75 cm above the
hob. When installing, strictly observe the minimum distance between the hob
and the extractor bonnet and follow the description of the work steps in the
"Wall mounting" section and all other instructions.
Installation with exhaust air opening to the outside
•
In the version with exhaust air to the outside, the vapours are extracted via an
exhaust air hose attached to the connection ring.
•
The diameter of the exhaust air hose must correspond to the diameter of the
connection ring.
•
The exhaust air hose must not be routed through a shaft together with gas
pipes, hot air pipes etc.
•
Route the exhaust hose as straight as possible away from the bonnet. The
maximum permissible outward bending is 120°.
•
If a smoke check damper is used or planned, check that it can open and close
freely after the exhaust air hose has been installed.
•
The cooker bonnet can be equipped with one (top) or two (top and rear)
exhaust openings. As a rule, the cooker bonnet is initially equipped for use of
the upper extractor opening as a cooker bonnet.
•
The openings that are not needed are covered with a plastic cover. This
plastic cover can be easily removed by turning it anticlockwise and optionally
attached to another opening that is not needed.
Use of the cooker bonnet as an exhaust bonnet (with exhaust air to the
outside):
•
If the cooker bonnet is equipped with a carbon filter at the factory, this must
be removed for exhaust air operation. Use only makes sense if you operate
your cooker bonnet in recirculation mode.