Logic
Denition
Conguration of
EXPI1 input on
input-output expan-
EXPI1
sion board.
1-2
Conguration of
EXPI2 input
on input-output
EXPI2
expansion board.
1-3
Conguration of
EXPO2 output
on input-output
EXPO1
expansion board
4-5
Conguration of
EXPO2 output
on input-output
EXPO2
expansion board
6-7
TRAFFIC LIGHT
Trac light
pre-ashing
PREFLASHING
TRAFFIC LIGHT
Steadily lit red light
RED LA P
ALWAYS ON
TABLE "C" RADIO MENU RADIO
Logic
Description
Add Start Key
Add start
associates the desired key with the Start command
Add 2ch Key
add 2ch
associates the desired key with the 2nd radio channel command.
Erase List
WARNING! Erases all memorized transmitters from the receiver's memory.
erase 64
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
ENGLISH
Cross out
Default
setting
used
0
Input congured as Start E command.
1
Input congured as Start I command.
2
Input congured as Open command.
3
Input congured as Close command.
4
Input congured as Timer command
5
Input congured as Timer command.
6
Input congured as Timer Pedestrian command
7
Input congured as Phot (photocell) safety.
8
Input congured as Phot op safety (photocell active during opening only).
9
Input congured as Phot cl safety (photocell active during closing only).
1
10
Input congured as Bar safety (safety edge).
Input congured as Phot test safety (tested photocell).
11
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input congured as Phot op test safety (tested photocell active during opening only).
12
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input congured as Phot cl test safety (tested photocell active during closing only).
13
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input congured as Bar safety (tested safety edge).
14
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
0
Input congured as Start E command.
1
Input congured as Start I command.
2
Input congured as Open command.
3
Input congured as Close command.
4
Input congured as Timer command
5
Input congured as Timer command.
0
6
Input congured as Timer Pedestrian command
7
Input congured as Phot (photocell) safety.
8
Input congured as Phot op safety (photocell active during opening only).
9
Input congured as Phot cl safety (photocell active during closing only).
10
Input congured as Bar safety (safety edge).
0
Output congured as 2
1
Output congured as SCA (gate open light).
2
Output congured as Courtesy Light command.
11
3
Output congured as Zone Light command.
4
Output congured as Stair Light.
5
Output congured as Alarm.
6
Output congured as Flashing light.
7
Output congured as Latch.
8
Output congured as Magnetic lock.
11
9
Output congured as Maintenance.
10
Output congured as Flashing Light and Maintenance.
11
Output congured as Trac Light control with TLB board.
12
output congured as barrier status
0
Pre-ashing switched o.
0
1
Red lights ash, for 3 seconds, at start of operation.
0
Red lights o when gate closed.
0
1
Red lights on when gate closed.
Optional extras
Radio Channel.
nd
33
GIOTTO BT A ULTRA 36 -