2. Remove the water deposit and empty it (figure 4).
3. Replace the water deposit inside the appliance and it will begin to function automatically.
Precautions: Do not remove the water deposit repeatedly, as if this is done within short
periods of time the compressor may be damaged. Always wait until the water deposit is full.
- Continuous water drainage.
1. Remove the rubber stopper situated at the base of the rear of the apparatus. (figure 5 A).
2. Extract the water deposit and seal the water inlet using the rubber stopper. (figure 5 B).
3. Connect a PVC tube of 11mm internal diameter to the rear water outlet. (figure 6). The
extraction tube should always lay flat on the floor with no obstruction that could impede the
free circulation of the water.
MAINTENANCE AND OPERATIONAL INSTRUCTIONS
1. Do not place the apparatus on an unstable floor as the apparatus could
become noisy in operation and suffer from vibrations.
2. Do not place any object on top of the dehumidifier.
3. To obtain optimum dehumidification, close all doors and windows in the room.
4. Disconnect the apparatus from the electricity supply before carrying out any maintenance
operation.
5. Clean the apparatus using a damp cloth. Do not use any detergents or abrasive products.
6. Clean the air filter every two weeks with hot water (40ºC), do not use alcohol, petrol,
acetone.... (figure 4)

TECHNICAL SPECIFICATIONS

Dimensions (mm)
Humidity renovation (l/day)
Operating voltage
Power
Resistance
Water deposit capacity
Working temperature
(15-35ºC the defrost function does not operate)
Net weight
Refrigeration gas
Working pressure

TECHNICAL ASSISTANCE

The extensive S&P Official Service Network guarantees your after sales service.
In the case that any anomaly is observed in the correct function of the apparatus, please
contact any of the aforementioned services, which will deal with your problem.
Any manipulation which is not strictly necessary for the installation of the apparatus, performed
by personnel who are not part of the Official Services of S&P, will invalidate the guarantee.
Width 274 x height 484 x depth258
10 l/day 30ºC RH80%
230V ~ 50Hz
226W
1.1 A
2.4l
5ºC – 35ºC
9.4 Kg
R134a, 170g
0.42Mpa – 1.7 Mpa