B B a a t t t t e e r r y y R R e e p p l l a a c c e e m m e e n n t t / / D D i i s s p p o o s s a a l l
B B a a t t t t e e r r y y R R e e p p l l a a c c e e m m e e n n t t
The battery should last the service life of the unit. Contact your Service Center for any
information you may need.
S S a a f f e e B B a a t t t t e e r r y y D D i i s s p p o o s s a a l l
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be
disposed of properly. Recycling is required, contact your local authority for
information. Failure to comply with local, state and federal regulations can result in
fines, or imprisonment.
W W A A R R N N I I N N G G S S
• • D D o o n n o o t t d d i i s s p p o o s s e e o o f f t t h h e e b b a a t t t t e e r r y y i i n n f f i i r r e e a a s s t t h h i i s s m m a a y y r r e e s s u u l l t t i i n n a a n n e e x x p p l l o o s s i i o o n n . .
• • B B e e f f o o r r e e d d i i s s p p o o s s i i n n g g o o f f t t h h e e b b a a t t t t e e r r y y , , p p r r o o t t e e c c t t e e x x p p o o s s e e d d t t e e r r m m i i n n a a l l s s w w i i t t h h h h e e a a v v y y - -
d d u u t t y y e e l l e e c c t t r r i i c c a a l l t t a a p p e e t t o o p p r r e e v v e e n n t t s s h h o o r r t t i i n n g g ( ( s s h h o o r r t t i i n n g g c c a a n n r r e e s s u u l l t t i i n n i i n n j j u u r r y y
o o r r f f i i r r e e ) ) . .
• • D D o o n n o o t t e e x x p p o o s s e e b b a a t t t t e e r r y y t t o o f f i i r r e e o o r r i i n n t t e e n n s s e e h h e e a a t t a a s s i i t t m m a a y y e e x x p p l l o o d d e e . .
1 1 2 2 V V o o l l t t D D C C C C h h a a r r g g i i n n g g A A d d a a p p t t e e r r P P l l u u g g F F u u s s e e R R e e p p l l a a c c e e m m e e n n t t
The fuse in the plug end of the 12 Volt DC Charging Adapter protects the adapter's
charging circuit. If the 127/220 Volt AC Charger operates, but the DC charging
adapter does not, then this fuse may be opened (blown).
To replace the fuse:
1. Unscrew the end cap of the DC plug (counterclockwise).
2. Remove spring center contact and fuse.
3. Check fuse with a continuity checker.
4. If blown, locate a replacement 8 amp/250 volt fuse.
5. Replace the fuse, spring, contact and end cap.
6. Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.
7. Test for proper operation of the 12 Volt DC Charging Adapter.
TROUBLESHOOTING
C C h h a a r r g g i i n n g g I I s s s s u u e e s s
N N o o B B a a t t t t e e r r y y S S t t a a t t u u s s I I n n d d i i c c a a t t o o r r L L E E D D s s L L i i g g h h t t W W h h e e n n C C h h a a r r g g i i n n g g
1. Check connection to the 127/220 Volt AC Charger or 12 Volt DC Charging
Port.
2. Check connection to AC or DC power source.
3. Confirm there is a functioning AC or DC current.
26
O O p p e e r r a a t t i i n n g g I I s s s s u u e e s s
T T h h e e A A r r e e a a L L i i g g h h t t i i s s o o p p e e r r a a t t i i n n g g , , b b u u t t t t h h e e S S p p o o t t l l i i g g h h t t i i s s n n o o t t . .
• SINGLE or TWIN must be selected on the Light Mode Switch a a n n d d the Trigger
depressed to operate the Spotlight.
• The Spotlight will not operate while charging using the 127/220 volt AC method.
Be sure all extension cords are disconnected from the AC charger before Spotlight
use. (The Spotlight can be operated while charging using the 12 volt DC method.)
• If you suspect the bulb is blown, check the filament. If the filament is coiled and
unbroken, the bulb is not blown. If bulb is blown, replace it.
N N o o n n e e o o f f t t h h e e l l i i g g h h t t s s a a r r e e o o p p e e r r a a t t i i n n g g . .
• The battery may be completely discharged. Charge the unit following the
directions on page 2.
• If the unit does not operate after recharging as directed, contact your Service
Center.
SPECIFICATIONS
Spotlight Bulb:
Dual 12 volt, H3 series, 75 watt
Battery:
Two maintenance-free, sealed lead acid,
6 volt, 6.0 amp hour
AC Charger:
VEC158BD-AR
VEC158BD-BR
VEC158BD-B2C
DC Plug Fuse
8A/250 V
12V DC (500mA)
15V DC (480mA)
12V DC (500mA)
27