Installation
Electrical Connection
Verify that the supply voltage is the same as that stated on
the heater (A.C supply only).
This heater is designed for use on a 208/240V 60Hz AC
single-phase supply. Connection requires a supply wire that
must consist of two wires plus ground and have a rating
capable of handling all loads on the circuit.
Make all relevant electrical connections within an installed
junction box and ensure all wiring meets all local electrical
and building codes. Where local code requires the
disconnection of all ungrounded supply lines, a double pole
isolating switch must be fitted to facilitate isolation.
Connection to the heater should be made using the provided
fitted cable clamp assembly at the back of the heater to meet
local code requirements.
WARNINg: Always use a qualified and licensed
electrician for all wiring and electrical connections.
Improper wiring could lead to a fire hazard.
Figure 2
C
DGP1000-B
560 mm / 22"
DGP1500-B
630 mm /
24.8"
DGP2000-B
800 mm /
31.5"
4
D
E
300 mm /
255 mm /
11.8"
10" MIN
300 mm /
255 mm /
11.8"
10" MIN
300 mm /
255 mm /
11.8"
10" MIN
Wall Mounting
!
IMPORTANT: The wall bracket supplied with the
appliance must be used. The heater should be positioned
observing the minimum clearances stated around the
heater (Figure 1).
WARNINg: Do not locate the heater immediately below a
fixed socket outlet or connection box.
①
Remove wall mounting bracket from the back of the
heater by depressing the spring latch at the top of each
bracket (Figure 2).
②
Fix the wall bracket securely to the wall through the four
(4) screw holes provided.
③
Present the heater to the wall bracket and engage lower
slots in the back with bracket.
④
Raise the heater to upright position and push the heater
onto bracket to engage top latch.
C
D
GFP500
390
300
GFP750
390
300
GFP1000
560
300
GFP1500
630
300
GFP2000
800
300
C
D
255 Min.
E
www.dimplex.com