18. Replacing the solenoid valve cartridge

18.1 Close the angle valves.
18.2 Trigger the tap.
18.3 Remove the battery compartment or wall installation power pack from the sensor.
18.4 Remove the sensor (b) from the solenoid valve cartridge (a).
18.5 Loosen the solenoid valve cartridge (a), using an open-ended wrench.
Important!
The solenoid valve cartridge must be connected before the power supply is
connected.
18.6 Reassemble in reverse order.

19. Spare parts

Description
Solenoid valve cartridge. . . . . . . . . . . 2030045522
Sensor type 8. . . . . . . . . . . . . . . . . . . 2030041487
Accessories
Order No.
Remote control. . . . . . . . . . . . . . . . . . 2030036654
2-button remote control . . . . . . . . . . . 2030036849
Battery compartment . . . . . . . . . . . . . 2000109466
Plug-in power supply . . . . . . . . . . . . . 2030039823