Troubleshooting; Technical Data; 8�1 Filter Unit; Flowmeter - Renfert POWER steamer water softener Manual De Instrucciones

Ocultar thumbs Ver también para POWER steamer water softener:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
7

Troubleshooting

Errors
POWER steamer is not
filled.
A negative value is
shown when the "Filter
status" (Chap. 5.2.2) is
displayed.
8

Technical data

8.1
Filter unit
Item no.
Dimensions
Height of the entire system / mm [inch]
Height of the filter cartridge / mm [inch]
Diameter of the filter cartridges / mm [inch]
Minimum distance to the floor / mm [inch]
Weight of the filter cartridge / kg [lbs]
Operating data
System pressure (without pressure surges) / hPa (bar) [psi]
Water temperature / ambient temperature / °C [°F]
8.2

Flowmeter

Item no.
Sensor unit
Connection thread
Inlet pressure (min/max) / hPa (bar) [psi]
Flow range / l/h [gal/l]
Pressure loss / hPa (bar) [psi]
Measurement (horizontal installation) / %
Water temperature (min/max) / °C [°F]
Ambient temperature (min/max) / °C [°F]
Dimensions (W x H x D) / mm [inch]
Installation position
Programming and display unit
Graphic display
Counter
Dimensions (W x H x D) / mm [inch]
Power supply, battery type
This unit corresponds to Part 15 of the FCC Rules�
Operation is subject to the following two conditions:
(1) This unit may not cause harmful interference and
(2) This unit must accept any interference received, including interference that may cause undesired
operation�
The label with the FCC ID and logo is located inside the battery compartment�
Cause
• Water connections assembled
against the direction of flow on the
filter head.
• Water supply is turned off.
• The filter capacity was not reset
(see Chap. 5.2.3) the last time the
filter was replaced.
Corrective action
• Check the assembly of the water connections� The
direction of flow is indicated on the filter head and the
sensor unit�
• Turn on the water supply�
• Reset the filter capacity (see Chap. 5.2.3).
Notes:
If the filter cartridge then remains in operation until the
filter replacement display is shown, this may be consi-
derably longer than intended for the filter cartridge. If
necessary, replace the filter cartridge with a new one
before the filter replacement display is shown.
1846 0100
+ 1846 0103
475 [18�7]
425 [16�7]
95 [3�7]
40 [1�6]
1�8 [4�0]
2000 - 8000 (2 - 8) [29 - 116]
Inlet 3/8" BSP IG / Outlet 3/8" BSP AG
1000 - 8000 (1 - 8) [14.5 - 116]
15 - 500 [3�96 - 132]
4 - 40 [37�4 - 104]
80 x 39 x 42 [3�15 x 1�54 x 1�65]
Horizontal recommended
5 digits in liters and gallons
Decreasing from 99999 to -9999
80 x 54 x 29 [3�15 x 2�13 x 1�14]
- 13 -
1846 0100
+ 1846 0104
410 [16�1]
360 [14�2]
136 [5�6]
40 [1�6]
3�2 [7�1]
4 - 30 [39 - 86]
1846 0101
≤ 500 (0.5) [7.25]
+/- 5
4 - 30 [37�4 - 86]
2 x AA