Check Valve: When the air compressor
is operating, the check valve is "open",
allowing compressed air to enter the
air tank.
When the air compressor
reaches "cut-out" pressure, the check
valve "closes", allowing air pressure to
remain inside the air tank.
Pressure
Release
Valve
Check Valve
Pressure Release Valve:
sure release valve located on the side
of the pressure switch, is designed to
automatically release compressed air
from the compressor head and the
outlet tube when the air compressor
reaches "cut-out" pressure or is shut
off. The pressure release valve allows
the motor to restart freely. When the
motor stops running, air will be heard
escaping from this valve for a few sec-
onds. No air should be heard leaking
when the motor is running or after the
unit reaches "cut-out" pressure.
Motor Overload Protector: This motor
has a manual thermal overload protec-
tor. If the motor overheats for any rea-
son, the overload protector will shut off
the motor. The motor must be allowed
to cool down before restarting.
restart:
1.
Place the On/Auto/Off lever in the
"Off" position.
2.
Allow the motor to cool.
3.
Depress the red reset button on the
motor.
Reset
Button
All manuals and user guides at all-guides.com
4.
Place the On/Auto/Off lever in the
"On/Auto" postion to restart the
motor.
Air Intake Filter (not shown): This filter
is designed to clean air coming into the
pump. This filter must always be clean
and ventilation openings free from
obstructions. See "Maintenance".
HOW TO USE YOUR UNIT
How to Stop:
1.
Set the On/Auto/Off lever to "Off".

Before Starting

unit until you read and understand
this instruction manual for safety,
operation
instructions.
Break-in Procedure
The pres-
Operation. Serious damage may
result if the following break-in
instructions are not closely followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been replaced.
1.
Make sure the On/Auto/Off lever is
in the "Off" position.
2.
Check oil level in pump. See Oil
paragraph in the Maintenance
section for instructions.
3.
Recheck all wiring. Make sure
wires are secure at all terminals
connections.
contacts move freely and are not
To
obstructed.
4.
Open the globe valve fully to
permit air to escape and prevent
air pressure build up in the air tank
during the break-in period.
5.
Move the On/Auto/Off lever to "On/
Auto" position. The compressor
will start.
6.
Run the compressor for 20 minutes.
Make sure the globe valve is open
and there is minimal air pressure
build-up in tank.
13 - ENG
Do not operate this
and
maintenance
Risk
of
Unsafe
Make
sure
all
N003195