Touch PC and log:
Error message
Description
Code 1
Equalization pressure too high
Code 2
Equalization pressure too low
Code 4
Warm-up pressure too high
Code 8
Warm-up pressure too low
Code 16
Warm-up time too long
Code 32
Warm-up time too short
Code 64
Changeover time too long
Code 128
Pressure build-up time too long
Code 256
Joining pressure too high
Code 512
Joining pressure too low
Code 1024
Joining time too short
Code 2048
Heating element temperature too
low
Code 4096
Interruption by operator
Code 8192
Ambient temperature not measured
Code 16384
Joining distance not adhered to
Code 32768
Heating element not removed
Code 65536
Second cooling time not adhered to
Code 131072
Heating element temperature too
high
Error Dataline 2.0
exe
Controls:
Error message
Description
SER
Service date reached, service
due
ERR1
Absolute pressure not reached
PE-2
Pressure sensor -24V defective
ERR5
Oil temperature 70°C – Stop!
HE-1
Heating element not connected,
sensor break
HE-0
Heating element too hot
HE-2
Heating element too cold
Troubleshooting
Test the hydraulics without the basic
machine, build up 100 bar, compare the
actual value with the target value – the
difference should be less than 5 bar
1) Compare the temperature of the
heating element with what is shown on
the display
2) Set parameter P002 to "0"
3) Protect the heating plate from strong
wind
Compare the temperature of the heating
element with what is shown on the dis-
play
Call up the "default" file in the middle of
the screen:
1) Close the "GO" screen
2) Double click on "default"
3) Restart the machine
Troubleshooting
Have service performed
Check oil level, check pressure sensor,
defective valve, defective motor
Replace pressure sensor
Wait until the oil temperature is below
50°C
Replace the sensor
Remeasure temperature, check settings,
replace sensor
Remeasure temperature, check settings,
replace sensor
ENGLISH