De Dietrich INIDENS 24 Manual De Usuario página 64

Ocultar thumbs Ver también para INIDENS 24:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
en
8 Troubleshooting
DISPLAY
DESCRIPTION OF PERMANENT FAULTS (RESET)
Group
Specific
code
code
Temperature measured by return sensor greater than
E.01
.12
flow temperature
E.01
.17
No water circulation (permanent)
E.01
.20
Maximum flue gas temperature reached
Total stoppage of the boiler (antifreeze function not
E.02
.13
active)
E.02
.17
Permanent communication failure in the PCB
E.02
.35
Critical safety device disconnected
Minimum pressure not reached after 6 minutes of au­
E.02
.39
tomatic filling
E.02
.47
Connection to external device unsuccessful
E.04
.01
Flow temperature sensor short circuited
E.04
.02
Flow temperature sensor disconnected
Maximum flow temperature exceeded or flow temper­
E.04
.03
ature sensor short circuited
E.04
.08
Maximum safe temperature value reached
64
INIDENS
CAUSE – Check/Solution
An installer is required for most checks and solu­
tions.
SENSOR/CONNECTION PROBLEM
Check that the sensors are positioned the correct
way around
Check that the flow sensor is in the correct posi­
tion Check the return temperature in the boiler
Check the operation of the sensors
INSUFFICIENT CIRCULATION
Check the installation pressure
Activate a manual venting cycle
Check the operation of the pump
Check the boiler/installation circulation
SENSOR ERROR
Check the operation of the temperature sensors
Check the temperature sensor connection
EXCHANGER ON FLUE GAS SIDE BLOCKED
Check the cleanliness of the exchanger
SIGNAL INDICATING BLOCKING INPUT
Contact X15 open, check connected devices
Parameter configuration error: Check setting
AP001
MAIN PCB ERROR
Check for any electromagnetic interference
Contact a qualified professional
COMMUNICATION FAULT
Start the auto-detect function (parameter AD)
Check the devices connected to contact X9
AUTOMATIC FILLING ERROR
Check automatic filling is working
ELECTRICAL CONNECTION ERROR
Start the auto-detect function (parameter AD))
Check the electrical connections of external devi­
ces.
SENSOR/CONNECTION PROBLEM
Check the sensor/PCB connection
Check the operation of the sensor
SENSOR/CONNECTION PROBLEM
Check the sensor/PCB connection
Check the operation of the sensor
INSUFFICIENT CIRCULATION
Check the boiler/installation circulation
Activate a manual venting cycle
Check the operation of the sensors
INSUFFICIENT CIRCULATION
Check the pressure in the installation
Switch on the manual degassing function
Check that the pump is working
Check the circulation in the boiler/installation
OTHER POSSIBLE CAUSES
Check the safety thermostat connection
Check that the safety thermostat is working cor­
rectly
7804840 - 02 - 20012022
Tabla de contenido
loading

Este manual también es adecuado para:

Inidens 20/24 miInidens 24/28 miInidens 30/35 mi

Tabla de contenido